The EST-5 is a Single Point Aluminium Load Cell suitable for use on platform scales measuring 600 x 600 mm. This load cell is available in capacities 50 kg and 100 kg.
Technical Information
Rated Load (kg)
50
75
100
150
200
250
300
500
635
1000
Technical specifications
Parameter
Sensitivity
Unit
mV/V
Specification
2 ± 0.1
Parameter
Nonlinearity
Unit
% FS
Specification
± 0.02
Parameter
Hysterisis
Unit
% FS
Specification
± 0.02
Parameter
Repeatability
Unit
% FS
Specification
0.01
Parameter
Creep
Unit
% FS / 30 min
Specification
± 0.02
Parameter
Zero Balance
Unit
% FS
Specification
± 2
Parameter
Zero Temperature Coefficient
Unit
% FS / 10°C
Specification
± 0.02
Parameter
Rated Output Temperature Coefficient
Unit
% FS / 10°C
Specification
± 0.02
Parameter
Input Resistance
Unit
Ω
Specification
420 ± 10
Parameter
Output Resistance
Unit
Ω
Specification
350 ± 3
Parameter
Insulation Resistance
Unit
MΩ
Specification
≥5000
Parameter
Supply Voltage
Unit
V
Specification
10 (DC / AC) MAX: 15 (DC / AC)
Parameter
Temperature Compensation Range
Unit
°C
Specification
-10~+50
Parameter
Safe Temperature Range
Unit
°C
Specification
-20~+60
Parameter
Safe Overload
Unit
% FS
Specification
120
Parameter
Cable
Unit
mm
Specification
Ø5 x 5000
Parameter
Cable Colour Code
Input: Red (+) Black (-)
Technical Information